Numerical and Experimental Investigations of Flow Pattern and Anti-Vortex Measures of Forebay in a Multi-Unit Pumping Station

Fan Yang,Yiqi Zhang,Chao Liu,Tieli Wang,Dongjin Jiang,Yan Jin
DOI: https://doi.org/10.3390/w13070935
IF: 3.53
2021-03-29
Water
Abstract:The forebay of a pumping station is an important building connecting the diversion channel and the intake pool. Based on the physical model test and research method of computational fluid dynamics (CFD) based on the improved fluid volume model, the flow field in a forebay of a multi-unit pumping station is analyzed in combination with the engineering practice of the Exi River flood discharge station in the Anhui Province, China. Aiming at the technical problems of a large-scale swing water area in the forebay internal flow field of a lateral intake pumping station, the technical problems are discussed. Different rectification measures are selected to adjust the flow pattern in the forebay of a pumping station. The internal rectification flow pattern in the forebay under different plans, the uniformity of flow velocity distribution in the measurement section, and the reduction rate of the vortex area are studied and compared, and the optimal plan is given. The results show that the flow pattern of the 7.5 m and 15 m solutions of the lengthened inflow wall is still poor, and the ability to eliminate vortices is not strong or even counterproductive. The combination plan of a rectifier sill and a rectifier pier has a better effect and can eliminate more than 90% of the vortex, but the uniformity of flow speed has not been significantly improved at the inlet of the pumping station; the combination plan of a rectifier sill and a diversion wall opening has the best effect; the reduction rate of the vortex area is more than 85%, and the velocity uniformity of three measuring sections is better than that of the original plan. The uniformity of flow rate near the pumping station is increased by 4% and that far away from the pumping station is increased by 13%. The combination plan of a rectifier sill and diversion wall with openings is recommended.
environmental sciences,water resources
What problem does this paper attempt to address?
This paper mainly discusses the flow state and anti-vortex measures in the inlet pool of a multi-pump station. The study is based on physical model experiments and computational fluid dynamics (CFD) using an improved fluid volume model. Combining with the actual engineering situation of a spillway in Anhui Province, the flow field inside the inlet pool is analyzed, and the technical problems of large-scale oscillating water flow in the internal flow field of the lateral inlet pump station are discussed. By selecting different rectification measures such as extending the inlet wall, rectification threshold, and rectification pier, the study investigates the influence of these measures on the flow state of the pump station inlet pool, including the adjustment of the flow state, the uniformity of flow velocity distribution, and the reduction rate of vortex area, and proposes the optimal solution. The study shows that extending the inlet wall to 7.5 meters and 15 meters has poor effect on improving the flow state, with weak ability to eliminate vortices or even counterproductive. The combination of rectification threshold and rectification pier can eliminate over 90% of vortices, but the uniformity of flow velocity at the entrance of the pump station does not improve significantly. The combination of rectification threshold and diversion wall opening has the best effect, with a reduction rate of vortex area exceeding 85%, and the uniformity of flow velocity at the three measuring points is better than the original solution. The uniformity of flow around the pump station and in the distance has increased by 4% and 13% respectively. Therefore, it is recommended to use the combination of rectification threshold and diversion wall opening. The innovation of this paper lies in the combination of model experiments and numerical simulations, using streamline judgment to analyze the improvement of flow state, vortex area, and uniformity of flow velocity, providing reference for related pump station projects.