Study on hydraulic characteristics of vertical pipe inlet/outlet of pumped storage plants

Weiping Cheng,Yunjin Hu,Junjun Zhang,Genhai Mao
2010-01-01
Abstract:The 2D slip physical hydraulic model and axisymmetric numerical models were applied to investigate the wake flow direction of the vertical pipe inlet/outlet outflow. The results of the 2D model experiment and the axisymmetric numerical simulations showed that the outflow of vertical pipe with the cover plate performed as jet flow, and the direction of wake flow changed with the water level. The wake flow would shift to the surface layer when the water depth was small and it would turn to the bed when the water depth was high. The 3D model experiment showed that the outflow head loss coefficient was 0.61 with an anti-swirl plate mounted above vertical inlet/outlet, and the factors were about 0.44~0.48 for other types of structures of statewide anti-swirl beam, flat anti-swirl beam or non anti-swirl beam. The inflow head loss factors were about 0.4 for all types of intakes. The model experiment results also suggested that it was able to provide uniformity flow with pipe diffuse angle of less than 9°. An individual big spiral vortex appeared above the inlet structure during the inflow model experiment under the conditions of high water level. As the water level went down, the big spiral vortex would collapse into several small ones, and the number of spiral vortexes was same as the number of the guide walls. When two intakes were working at the same time, spiral vortexes would interact, one was dextrorotatory and another was levorotatory.