Operating optimization of oxidation subsystem of wet flue gas desulfurization system of 1000 MW coal-fired unit

FAN Hai-dong,CHEN Zhu,ZHAO Zhong-yang,LIANG Cheng-si,ZHENG Cheng-hang,GAO Xiang
DOI: https://doi.org/10.3785/j.issn.1008-973x.2023.04.004
2023-01-01
Abstract:A model of the oxidation process in the wet flue gas desulfurization(WFGD) based on the mechanism of forced oxidation and natural oxidation process was established aiming at the problems of excessive oxidation air and high energy consumption of oxidation system under variable load and SO 2 mass concentration operation existing in the application of limestone-gypsum WFGD technology. The influence of key parameters such as the O 2 volume fraction in the flue gas, the diameter of bubbles or droplets and reaction enhancement factor on forced oxidation rate and natural oxidation rate was analyzed. A real-time operation optimization method of oxidation system based on the above-mentioned oxidation process model was proposed, and an industrial test was conducted on a 1 000 MW desulfurization unit. Results showed that the root-mean-square error(RMSE) of the variation of sulfur was less than0.15 mol/m~3. The natural oxidation rate fluctuated between 10% and 35% and the demand for oxidizing air fluctuated between 107 m~3/min and 360 m~3/min with the unit load fluctuating between 520 MW and 1 000 MW. The real-time operating optimization method of the oxidation subsystem can reduce the energy consumption by 23.7% compared with operating at rated power under the premise of enough oxidation rate of the WFGD system.