Evaluation on Operation Stability of a Flue Gas Desulfurization System After Ultra-low Emission Retrofit of the Coal-fired Unit

Weiming TENG,Qingyi LI,Chenghang ZHENG,Daqing HU,Haidong FAN,Li LI,Xiang GAO
DOI: https://doi.org/10.3969/j.issn.1674-7607.2017.12.008
2017-01-01
Abstract:An evaluation system was established for the desulfurization performance of a 1 000 MW coalfired power plant after ultra-low emission retrofit,based on the consumption of material and energy,and the interrelation among the unit load,the inlet and outlet concentration of SO2,the desulfurization efficiency and the slurry pH,etc.,so as to evaluate the running status,reliability and stability of the desulfurization unit in detail.Results show that the outlet concentration of SO2 is positively related to the inlet one.When the pH value of gypsum slurry is kept in 5.0-5.6,there exists a linear correlation between the outlet concentration of SO2 and the pH value.The consumption of limestone has a linear relationship with the emission rate of SO2.The relatively stable content of gypsum slurry is found to be able to meet the requirement of process design.After ultra-low emission retrofit,the water consumption reduces,the power consumption rises,the outlet concentration of SO2 drops significantly,the attainment rate reaches 99.59%,and the SO2 concentration at unit outlet gets stable,indicating obvious effects of the retrofit.
What problem does this paper attempt to address?