EMISSIONS IN COAL-FIRED FLUE GAS CHARACTERISTICS OF SO3 AND PARTICULATE FROM SHANXI POWER PLANT

Wei YANG,Bin-bin SUN,Xue WANG,Ting-yu ZHU,Jia-nan WANG,Bin WANG,Min-wu WANG
DOI: https://doi.org/10.13205/j.hjgc.201801017
2018-01-01
Environmental engineering
Abstract:A 330 MW power plant coal-fired units of the pollutant removal equipment (SCR denitrification tower,electrostatic precipitator,wet electrostatic precipitator) were modified,and the emissions were detected.The pollutants concentration of SO2 、NOx and particulates were 5.1,4.1,4.2 mg/m3,meeting the ultra-low emission standards.The paper used virtual impact sampler to detect particulates grading-concentration in wet electrostatic precipitator.The removal efficiency of PM2.5,PM2.5-10,PM >10 were 83.29%,93.06%,96.51%,respectively.The PM2.5 removal effect was the best by wet electrostatic precipitator.The element and particle size of particulates from the import and export of electrostatic precipitator were analyzed.The synergistic removal efficiency of SO3 and alkaline substances in particulates was 10.09%,particulates with size greater than 13 μm tend to be completely removed in the electrostatic precipitator.