Design and Prototype Test of a High-Sensitivity Reentrant-Cavity Based Schottky Pickup.

Minwen Wang,Xin Zhuo,Mingtong Zhao,Mengtong Qiu,Wei Chen,Zhongming Wang
DOI: https://doi.org/10.1063/5.0134286
IF: 1.6
2023-01-01
Review of Scientific Instruments
Abstract:Schottky diagnostics is an important measure for the debunched beam during the injection phase of the Xi’an Proton Application Facility (XiPAF). The existing capacitive Schottky pickup has a relatively low sensitivity and a poor signal-to-noise ratio for the low-intensity beam. A resonant Schottky pickup based on the principle of a reentrant cavity is proposed. The effects of cavity geometric parameters on cavity properties are systematically studied. A prototype was built and tested to validate the simulation results. The prototype has a resonance frequency of 24.23 MHz, a Q value of 635, and a shunt impedance of 19.75 kΩ. The resonant Schottky pickup has the capability to detect as few as 2.3 × 106 protons with an energy of 7 MeV and a momentum spread of about 1% at the injection phase of XiPAF. The sensitivity is two orders of magnitude higher than the existing capacitive pickup.
What problem does this paper attempt to address?