Comparison of Organic Coolants for Boiling Cooling of Proton Exchange Membrane Fuel Cell

Qingshan Li,Chenfang Wang,Chunmei Wang,Taotao Zhou,Xianwen Zhang,Yangjun Zhang,Weilin Zhuge,Li Sun
DOI: https://doi.org/10.1016/j.energy.2022.126342
IF: 9
2023-01-01
Energy
Abstract:Cooling and temperature homogeneity are the key technical problems for the proton exchange membrane fuel cell (PEMFC) thermal management. In this paper, a one-dimensional model of a PEMFC with phase-change cooling (flow boiling cooling) is proposed for PEMFC thermal management, and the heat transfer of micro-channel flow boiling is integrated with PEMFC cooling. Five organic coolants (Novec 649, HFC-365mfc, HFE-356mec, HFE-347pcf2, and HFE-7100) and single-phase water are compared by the PEMFC average temperature of the catalyst layer (ATCL) and temperature difference of the catalyst layer (TDCL). The PEMFC temperature characteristics with organic coolant are investigated in detail. The results indicate that HFE-7100 exhibited the lowest ATCL and minimum TDCL among the coolants. The maximum TDCL of HFE-7100 is 5.5 K at current density of 1.2 A/cm2, which can completely keep the PEMFC operating temperature at proper and uniform conditions. The minimum ATCL of Novec 649 is over 353 K, which dissatisfies the cooling demand. The TDCLs of PEMFCs with different organic coolants have a minimum value when the coolant outlet vapour mass fraction is 0.4. Temperature uniformity should be the most important factor for mass flow control in PEMFCs using organic coolants.
What problem does this paper attempt to address?