Suppression of Low-Frequency Magnetic Interference on Eddy Current Displacement Sensor with Nanometer Resolution

Chengliang Pan,Shupeng Ren,Fei Yang,Chao Shi,Heng Zuo,ZhiHua Feng
DOI: https://doi.org/10.1109/ICSMD50554.2020.9261737
2020-01-01
Abstract:Since eddy current displacement sensors (ECDSs) are based on phenomenon of electromagnetic induction, their measurement results would be seriously disturbed by the magnetic interference. Traditional solution is to add a shield integrated in the sensing probe, but it will also affect the property of sensing coil. In this paper, an alternative solution is proposed to suppress the low-frequency magnetic interference by high-frequency signal conditioning circuits with deliberate filtering segments. Prototype ECDS provides a resolution of 20 nm with measuring range of 50 μm and bandwidth of 3 kHz, under magnetic interference of 6000 A/m at 1 kHz.
What problem does this paper attempt to address?