Experimental Study on Dynamic Effect of External Insulation on Indoor Thermal Environment and Energy Consumption

Luyao Guo,Yuxuan Liao,Zhu Cheng,Hanjie Zheng,Lei Guo,Enshen Long
DOI: https://doi.org/10.1016/j.enbuild.2022.112299
IF: 7.201
2022-01-01
Energy and Buildings
Abstract:In this paper, two identical model buildings were built, one of which adopted 38 mm Expanded Polystyrene (EPS) board as the external insulation. Under the same heating set-point temperature, the dynamic change process of indoor thermal environment and heating energy consumption of EPS insula-tion building and non-insulation Reference building was compared and monitored. Results show that under the same heating set-point temperature, the indoor temperature of the two buildings can quickly approach the set value in about 20 min. However, the temperature rise of the internal surface of the wall lags behind. After several hours, the advantage of the temperature rise of the internal surface of the EPS building gradually appeared. The energy consumption of the two buildings is similar in the initial heating period of 20 min, and the energy saving rate of EPS building increases slowly with the increase of the heating duration. The energy saving rate is about 1%-26% in the range of 0.5-8 h intermittent heating in hot summer and cold winter zone. The change curve of cumulative temperature rise ratio with heating time is proposed to evaluate the dynamic improvement effect of external insulation on indoor thermal environment. This research provides a reference basis for the development of energy conservation.(c) 2022 Published by Elsevier B.V.
What problem does this paper attempt to address?