Abstract:Large-scale solid oxide fuel cell (SOFC) stationary power generation systems require multi-stack SOFC integration. System consistency has a significant impact on stable, long-term operations. Investigations on the flow and temperature distributions of the system and effective thermal management are necessary to improve system consistency. In this study, a multi-stack SOFC system was modeled based on the flow network method. The flow and thermal distributions and performance were investigated by considering air stoichiometries of 1.5, 2.0, and 2.5. A thermal management strategy using bypass valves is proposed to solve the maldistribution issue of the system. By controlling the opening of the bypass valve, the intake air temperature of different stacks can be adjusted according to the stack temperature. The results indicate that a maximum temperature difference of 60 K can be reduced to 0 K through the proposed thermal management strategy in a 5 kW multi-stack system. The application of the bypass valve enables the system to attain temperature consistency, and the thermal efficiency of the entire SOFC combined heat and power system can be increased by up to 50% at the set temperature.