Research and Application Analysis on the Pollution Control of Tail Gas Emissions from Co2 Capture Absorber

Shijian Lu,Miaomiao Liu,Mengxiang Fang,Juanjuan Zhang,Feng Wang,Qingfang Li,Chao Li,Jian Zhang,Hongfu Chen
DOI: https://doi.org/10.2139/ssrn.4088684
2022-01-01
SSRN Electronic Journal
Abstract:In this study, the emission and control of flue gas pollutants in CO2 chemical absorption system was studied. It was found that the condensation nuclei in the gas were the main factor that affected aerosol emissions, and reducing the number of condensation nuclei in the flue was the most direct method to control pollutant emissions after the water washing tower. Higher temperature of lean liquid will increase absorbent emission; however, the water washing tower could effectively control this increase. Reducing the lean liquid load could also significantly increase the absorbent emissions, and an appropriate reduction in lean liquid load combined with a certain absorption intensification indicated effective regulatory means. At the same time, based on the world's largest flue gas CO2 capture project-2 million tons/year flue gas CO2 capture project of Shengli Power Plant, the combined process of water washing and dry bed was studied. A control scheme for dry bed and two-stage water washing was put forward, which effectively controlled the emission of large particles aerosol. The decline rate of absorbent emission is 24.9%-41.8%, reaching 0.180kg/t CO2, which reach the international leading level.
What problem does this paper attempt to address?