ICOPE-15-C042 130t/h Coal-fired boiler low NOx transformation and numerical simulation

Shao-bo GUO,Shuai MA,Lei GUO,Bin YAO
DOI: https://doi.org/10.1299/jsmeicope.2015.12._icope-15-_134
2015-01-01
The Proceedings of the International Conference on Power Engineering (ICOPE)
Abstract:Low NOx combustion technology is a clean economic and extremely effective method to reduce NOx emission of coal-fired boiler. It is critical to study low NOx combustion for coal-fired boiler denitration transformation. In low NOx transformation, NOx emission of tangential firing pulverized coal boiler depends on the distance between SOFA wind and upper primary air, the tangential circle size and the amount of SOFA wind. Besides, the arrangement of third wind scale is a long-standing and actual difficult problem, especially to meager coal. In this paper, experimental and numerical methods are conducted to study NOx emission of the transformed 130t/h coal boiler. The numerical simulation shows that the optimal distance between SOFA wind and upper primary air depends on the volatiles and calorific value of coal. The temperature in outlet of furnace is more uniform when the arrangement of SOFA wind takes anti-clockwise. What's more, when the amount of SOFA wind accounts for about 15%〜20% of the amount of secondary air, the NOx emission was significantly reduced without reducing the boiler efficiency. According to the simulation results and practical condition, the 130t/h boiler was retrofitted. Experimental results showed that the NOx emission reduced from 310ppm to 168ppm, with 2.5%〜3.0% oxygen component in flue gas and lower SOFA wind opened.
What problem does this paper attempt to address?