Thin Film Shape Memory Microcage for Biological Applications

Y. Q. Fu,J. K. Luo,S. E. Ong,S. Zhang
DOI: https://doi.org/10.1017/cbo9780511635366.019
2009-01-01
Abstract:This chapter focuses on the fabrication and characterization of a microcage for biopsy applications. A microcage based on a free-standing film could be opened/closed through substrate heating with a maximum temperature of 90 °C, or Joule heating with a power less than 5 mW and a maximum response frequency of 300 Hz. A TiNi/diamond-like-carbon (DLC) microcage has been designed, analyzed, fabricated and characterized. The bimorph structure is composed of a top layer of TiNi film and a bottom layer of highly compressively stressed DLC for upward bending once it is released from the substrate. The fingers of the microcage quickly close through the shape memory effect once the temperature reaches the austenite transformation point to execute the gripping action. Opening of the microcage is realized by either decreasing the temperature to make use of the martensitic transformation or further increasing the temperature to use the bimorph thermal effect. The biocompatibility of both the TiNi and DLC films has been investigated using a cell-culture method.
What problem does this paper attempt to address?