Investigation of anti-ablation property of Cf/HfC composite prepared at 1900°C by reactive melt infiltration

Y. C. Ye,H. Zhang,Y. G. Tong,L. A. Zhu,S. X. Bai,K. Chen
2012-01-01
Abstract:A quarternary Hf alloy (50Hf10Zr40Si3Ta) has been prepared and infiltrated into a C-C preform at 1900°C, much lower than the alloy melting point, to obtain the Cf/HfC composite, whose linear ablation rate by laser has been tested to be only 8×10 mm/s. The composite exhibits excellent oxidation-resistant and ablation-resistant properties because of the behavior of various oxides formed during the ablation by laser. First, a large amount of heat was taken away with the melt and evaporation of SiO2, HfO2, ZrO2 and Ta2O5. Second, HfO2, ZrO2 and Ta2O5 in liquid state at the ablated temperature flew and sealed the cracks and holes in the composite. Last, a Ta2O5•mHfO2 melt with a low vapor pressure and high viscosity was formed, which would block the diffusion of the oxygen to the inner of the composite.