Achievements of active feedback control of divertor heat load in EAST Plasma Control System

Q. P. Yuan,K. Wu,D. Eldon,L. Wang,G. S. Xu,J. C. Xu,K. D. Li,Y. M. Duan,R. R. Zhang,Z. P. Luo,J. B. Liu,D. Fang,B. J. Xiao,H. Q. Wang,A. Hyatt,Jayson Barr
2019-01-01
Abstract:EAST has achieved a total power injection up to 0.3 GJ with ITER-like water-cooled tungsten (W) mono-block divertor. The high performance and long pulse operation will lead to more challengeable divertor heat load, which may damage the divertor target material. Based on the knowledge of divertor physics and plasma-wall interaction (PWI) research, a number of promising methods on divertor issue handling, including advanced snow-flake shape, radiation power elevation and divertor detachment operation have been demonstrated in EAST experiments. This paper will focus on the latter two means and introduce the achievements made from active divertor heat load feedback control in EAST plasma control system (PCS) [1].
What problem does this paper attempt to address?