Aerodynamic Characteristics of a 350-Mwe Supercritical Utility Boiler with Multi-Injection and Multi-Staging: Effects of the Inner and Outer Secondary Air Distribution in the Burner
Minhang Song,Lingyan Zeng,Zhichao Chen,Zhengqi Li,Min Kuang
DOI: https://doi.org/10.1016/j.joei.2016.10.007
IF: 6.47
2016-01-01
Journal of the Energy Institute
Abstract:Prior to commercial operation of the first-ever 350-MWe supercritical down-fired boiler incorporating multiple injection and multiple staging combustion technology, cold modeling experiments varying the inner-to-outer-secondary air (ISA/OSA) ratio (applying ratios of 0:10, 2:8, 5:5, 6:4 and 10:0) were performed within a 1:13 scale model of the boiler furnace. The aim of these trials was to establish an optimal inner and outer secondary air distribution model for the burner in the full-scale furnace. At ratios of 0:10 and 2:8, the fuel-rich flow apparently diffused toward the furnace center zone after leaving the corresponding nozzle outlet, resulting in the formation of relatively small recirculation zones below the arches and independent fuel-rich and fuel-lean flow streamlines. In contrast, at ISA/OSA ratios greater than or equal to 5:5, the strengthened carrying effect of the inner secondary air significantly reduced the diffusion of the fuel-rich flow. Consequently, the fuel-rich and fuel-lean flow streamlines combined in the middle region of the lower furnace and the recirculation zones under the arches enlarged. As the ISA/OSA ratio was increased from 0:10 to 10:0, the line fitting slopes for the downward airflow decay curves increased from 1.8 to 3.0, meaning that the downward airflow decayed more rapidly, such that the penetration depth was reduced. Finally, at ISA/OSA ratios of 0:10 and 2:8, the initial flow-field deflection was observed to gradually adopt a symmetrical pattern.