Digital Frequency Sweeping Approach For Alternating Current Field Measurement

Han Yuqin,Zu Xianfeng,Kang Zhongwei
2006-01-01
Abstract:Precise positioning and sizing of flaws holds the important position in life evaluation of a structure with flaws. Alternating current field measurement (ACFM) is a new NDT method to evaluate surface flaws and is widely used in on-line inspection of structures for its non-contacting and non-calibrating characteristics. But it is difficult to size the flaw depth; the digital frequency sweeping approach is applied to remedy this shortage. The penetrating depth of eddy-current and phase lag, which vary as a function of frequency. are the essential parameters for the detection of flaw depth. The detection of material features or the non-damage quantity detection of internal flaws can also be finished in accordance with the mathematical calculations by measuring the impedance and the according voltage of the pick-up coil. In the end, a novel method of direct digital synthesizing frequency sweep signal is presented. The desired signal is generated when the sequence-signal passed through A/D converter and low pass filter. Start frequency, stop frequency and sweep time of the frequency-sweeping signal can be presented freely and controlled accurately.
What problem does this paper attempt to address?