Construction Of Nano-Array Electrode Material For Amperometric Detection Application

Yibing Xie
2009-01-01
Abstract:The electrochemical biosensor with a well-aligned nanotube array structure has been developed for amperometric detection and quantitative determination on the basis of bioelectrocatalysis mechanism. The independent and free-standing titania nanotube array has been successfully fabricated through an electrochemical anodization process of titanium sheet precursor in a fluoride-containing electrolyte, which can act well as a suitable electrode material for the biosensor application due to its high surface area and superior biocompatibility. In view of a more feasible loading of enyzme probes in accessible tubular channels, nanotube morphologies have been promoted by expanding tube diameter from 60 to 110 nm and increasing tube length from 520 nm to above 920 rim when anodization process at voltage of 20 V in acidic aqueous electrolyte has been adjusted into that at 60 V in neutral ethylene glycol/glycerol electrolyte. The functionalization modification of the titania nanotube array has been sequentially achieved by filling highly-bioactive glucose oxidases into as-formed nanotubes and then electropolymerizing pyrrole monomer into conductive polypyrrole for an interfacial immobilization of these bioactive enzymes. Morphology & microstructure characterization, electrochemical properties and bioelectrocatalytic reactivities of composite electrodes have been fully investigated. Electrochemical impedance spectroscopy has been employed to investigate the electrical conductivity and capacitance analysis. The direct amperometric detection of hydrogen peroxide through a direct electro-reduction reaction can be well fulfilled on bare titania nanotube array with a detection limit up to 2.0x10(-4) mM for ordinary nanotubes and 2.2x10(-4) mM for long nanotubes. A nano-array biosensor based oil the glucose oxidase-titania/titanium composite electrodes have been assembled in a conventional three-electrode system for amperometric detection and quantitative determination of glucose concentration in a pH 6.8 phosphate buffer solution at a potentiostatic condition of -0.4 V vs. the saturated calomel electrode. The glucose oxidase biosensor with a well-constructed nanotube array structure show an excellent performance with a high detection sensitivity of 45.5 mu A mM(-1) cm(-2), a fast responding time of 5.6 s and a very low detection limit of 2.0x10(-3) mM. A good operational reliability has also been achieved with a relative standard deviation below 3.0%. Such a well-designed biosensor with a desired nanotube array structure can consequentially contribute to the potential application of molecule detection and quantitative determination.
What problem does this paper attempt to address?