Analysis of Assembly Errors and Design of Precise Micro-regulator for Micro-hemispherical Resonator Gyroscope (Mhrg)
XI Xiang,XIAO Dingbang,LI Wei,LU Kun,SHI Yan,YUAN Chao,WU Xuezhong
DOI: https://doi.org/10.3901/jme.2020.13.077
2020-01-01
Journal of Mechanical Engineering
Abstract:: The forming mechanism of assembly error of micro-hemispherical resonator gyroscope (mHRG) is analyzed, and the requirement of assembly accuracy is calculated. In case that the anchor diameter of mHRG structure is 1 mm, if the uniformity of assembly clearance is less than 10%, the height deviation of the anchor surface needs to be less than 0.1 μ m. By using numerical calculation and finite element model, the effects of assembly errors on electrode driving ability, static capacitance, stiffness regulation and first-order mode shape are respectively studied. The results show that the uneven gap between electrodes influences detecting, driving and stiffness regulation as a function of 1st, 2nd, 3rd power, and at the same time it can cause a slight structural swing. In order to improve the uniformity of electrode assembly, a micro-regulator based on flexible reduction unit is designed. By using the adjusting screw and flexible cushion, the quartz glass substrate can generate a 2-DOF micro-swing, thus achieving high precise assembly. Test results show that the average capacitance error of the mHRG is about 30% ~ 40% after assembly, but parasitic capacitances are introduced. After eliminating parasitic influence, the average capacitance error is 12%.