Experimental study of micro-mixing performance of split and recombine micromixer and interdigital micromixer

Ming LI,Yao WANG,Na ZHANG,Zheng-ling REN,Xue-hu MA,Xue-fei LI
DOI: https://doi.org/10.7511/dllgxb201605001
2016-01-01
Abstract:The iodide-iodate parallel competing reaction system is used to investigate the micro-mixing performance of two micromixers:a split and recombine micromixer and an interdigital micromixer.The effects of H+ concentration,Re and volume flow ratio of mixing streams on the segregation index in the micromixers are experimentally studied,and the experimental results are analyzed theoretically.The results indicate that,for both micromixers,the proper H+ concentration range is 0.02-0.04 mol/L to obtain the best micro-mixing performance when the volume flow ratio of mixing streams is 1 .It is found that the segregation index increases with the volume flow ratio,which suggests that the micro-mixing performance is lowered.The increase of Re is beneficial to improve the efficiency of micro-mixing.The micro-mixing performance of the split and recombine micromixer is better than that of the interdigital micromixer at the same Re for the studied range of Re.
What problem does this paper attempt to address?