Design and Experimental Study of Staggered Oriented Ridges Micromixers

LIU Su-fen,FU Xin,YANG Hua-yong,XIE Hai-bo
DOI: https://doi.org/10.3785/j.issn.1008-973x.2005.12.014
2005-01-01
Abstract:To enhance fluid mixing in microfluidic system,a novel three-dimensional static micromixer was designed based on laminar flow mixing principle.With the staggered oriented ridges arranged periodically in the microchannel,the transverse components of flow were generated under a steady axial pressure gradient to stir the fluid and effectively enhance mixing in the microchannel.The distribution of velocity field in the static micromixers was investigated with the computational fluid dynamics method,and the mixing principle in the micromixer was analyzed.The performances of micromixers were measured through Rhodamine dye and deionized water mixing experiment,and the relationships of the mixing degree with the structural parameters and the Reynolds number were quantitatively investigated.Experimental results show that the staggered oriented ridges Ⅱ(SOR-Ⅱ) micromixer can achieve good mixing in low and high Reynolds number,while the staggered oriented ridges Ⅰ(SOR-Ⅰ) micromixer can achieve good mixing only in high Reynolds number.
What problem does this paper attempt to address?