Measurement of acoustic attenuation coefficient of material with the stepped sample

Xiaorong LIU,Xiping HE,Dong CUI,Shengping HE,Tao NI,Rensong CHEN
DOI: https://doi.org/10.15983/j.cnki.jsnu.2015.02.224
2015-01-01
Abstract:In order to measure the acoustic attenuation coefficient more precisely,the influence of acoustic reflection and acoustic transmission at the upper and lower interfaces of a material are considered.The expression of acoustic attenuation coefficient is derived strictly.The traditional test sample is changed into a stepped one.With the improvement of one tested echo into two test-ed echoes at the thinner and thicker ends of the stepped sample,the pressure ratio before and af-ter attenuation can be obtained.Thus the precise acoustic attenuation coefficient of the material is available.Since the acoustic attenuation induced by reflection and transmission is excluded,the a-coustic attenuation coefficient measured by such methed is reduced 25% comparing with tradition-al methed.
What problem does this paper attempt to address?