A new technique for the measurement of the normal incidence absorption coefficient using an impedance tube and a single microphone with fixed position

Cedric Vuye,Steve Vanlanduit,Karl Van Nieuwenhuyse,Patrick Guillaume
DOI: https://doi.org/10.1121/1.2934373
2008-05-01
The Journal of the Acoustical Society of America
Abstract:The normal incidence absorption coefficient of acoustic materials can be measured inside an impedance tube with different settings for the microphone(s). The two most widespread techniques are the standing wave method using a probe microphone and side-mounted two-microphone techniques. Errors that can occur here are related to phase mismatch between the two microphones and the knowledge of the exact locations of the (acoustic centre of the) microphones and test sample. These problems have (partially) been solved by, for example, calibrating the microphones by swapping them and calculating a calibration transfer function or by using one microphone techniques. In this article we will present a novel technique which will also avoid the need for the knowledge of the exact microphone location by continuously moving the sample under test. Different results will be presented and compared to the traditional techniques.