Experimental Study on the Influencing Factors of Metastable Zone of FGD Wastewater in Coal-fired Power Plants

Xi-Ning CHENG,Jing-Yu RAN,Li ZHANG,Ge PU,Zhong-Qing YANG,Chang-Lei QIN,Xue-Seng DU
2017-01-01
Journal of Engineering Thermophysics
Abstract:The treatment technology of spray-evaporating FGD wastewater using flue gas waste heat presents a wide application prospect,but this technology has some problems.To assess the effect of the Technology on the subsequent equipment,it is critical to study the influencing factors of metastable zone of FGD wastewater.With the laser monitoring observation technique,this study collected fundamental thermodynamic measurement data regarding the solubility and supersolubility of the major components of FGD wastewater in the deionized water.Based on these data,this study discusses the influences of metal ions,stirring rate,pH and fly ash on the metastable zone of the major components of FGD wastewater.Specifically,this study finds that metal ions expands metastable zone,which is the primary cause of flue dust deposition,while the mixture turbulence intensity of waste water and gas,weak acid environment and fly ash narrow metastable zone,which reduces the flue dust deposition.
What problem does this paper attempt to address?