Accuracy of hemodialysis adequacy evaluated by an online clearance monitor
GAO Jiayuan,LU Renhua,ZHU Mingli,ZHANG Weiming,QIAN Jiaqi,NI Zhaohui,YAN Yucheng
2011-01-01
Abstract:Objective To analyze the accuracy of hemodialysis adequacy evaluated by an online clearance monitor(OCM),and to investigate the value of its application.Methods Totally 19 anuric maintenance hemodialysis patients were included in the present study.Drained dialysate samples were collected at 0.5,1,2,3 and 4 h after dialysis by both partial dialysate collection method(PDC)and total dialysate collection method(TDC).Urea nitrogen levels were assessed to evaluate the agreement between PDC and TDC and to calculate Kt/V by direct dialysate quantification method(DDQ,DDQ Kt/V).Blood urea nitrogen(BUN)was measured at the beginning,the end as well as 30 min after dialysis.Single pool Kt/V(Sp Kt/V)by Daugirdas II formula was calculated.Equilibrated Kt/V(Eq Kt/V)and rate adjusted Kt/V(Ra Kt/V),which are close to double pool Kt/V,were also calculated.OCM Kt/V was provided by OCM module from Fersenius.The values and correlation of Kt/V from different methods were compared and analyzed.Urea distribution volume(Vurea)from the three formulas(Watson formula,Hume-Weyers formula,and weight derivation formula)which were internally installed in OCM were compared with the standard Vurea level from direct dialysate quantification.Results Urea nitrogen was(5.15±1.85)mmol/L in the dialysate samples of PDC,which had no significant difference from that of TDC [(5.37±1.90)mmol/L,P=0.534].Pearson correlation test showed that the urea nitrogen levels from the two methods were significantly correlated(r=0.955,P<0.05).Bland-Altman analysis indicated agreement in the levels of urea nitrogen between two methods.The value of OCM Kt/V(1.24±0.24),Ra Kt/V(1.39±0.24)and Eq Kt/V(1.41±0.27)were close to that of DDQ Kt/V(1.34±0.26,P>0.05),while Sp Kt/V(1.58±0.27)was significantly higher than DDQ Kt/V,OCM Kt/V,Ra Kt/V and Eq Kt/V(P<0.05).Pearson correlation test showed that OCM Kt/V had significant correlation with DDQ Kt/V,Sp Kt/V,Ra Kt/V and Eq Kt/V(r=0.706,0.594,0.605,0.731,all P<0.05);the values of OCM Kt/V with DDQ Kt/V,Eq Kt/V and Ra Kt/V were significantly higher than that with Sp Kt/V.DDQ Kt/V was significantly correlated with Sp Kt/V,Ra Kt/V and Eq Kt/V(r=0.901,0.891,0.963,all P<0.05).Vurea level calculated from all three OCM internally installed formulas were(34.10±4.25),(35.93±4.28)and(33.79±6.93)L,respectively,significantly higher than that from DDQ([28.23±9.27] L,P<0.05).Conclusion OCM Kt/V values and DDQ Kt/V values are close values and are well correlated with each other.OCM may be a satisfactory method to evaluate the actual delivered dialysis dose for hemodialysis patients,with advantage of quick on-line real-time monitoring.It should be extensively applied,but still need further verification.