Comparison of the Watson formula and bioimpedance spectroscopy for measuring body volume and calculating kt/V in patients with peritoneal dialysis

Sixiu Liu,Yuan Feng,Qingyan Zhang,Jian Lu,Nan Li,Ying Liu,Chunming Jiang
DOI: https://doi.org/10.1080/0886022x.2024.2313360
IF: 3.222
2024-02-13
Renal Failure
Abstract:Background: Ascertaining the total body water (V), usually obtained by the Watson formula or bioimpedance spectroscopy (BIS), is crucial for the calculation of Kt/V in patients with peritoneal dialysis (PD). The aim of our study was to compare two different methods of determining V and explore which one is suitable for clinical application. Methods: This was a retrospective observational study. V was determined using the Watson formula (Vwat) and BIS (Vbis). The differences between Vbis and Vwat and between Kt/Vbis and Kt/Vwat were assessed. The patients were allocated to different groups according to the Kt/Vwat and Kt/Vbis values. Clinical parameters were compared between these groups to investigate which method of obtaining the Kt/V value was more suitable. Results: 150 patients on PD were included. Vwat was significantly higher than Vbis, apart from in female patients with volume overload. Consequently, weekly Kt/Vwat was lower than Kt/Vbis in these patients. A significant negative correlation between mean Vwat-Vbis and overhydration values was also found. Moreover, through uniform manifold approximation and projection analysis, a clustering tendency between patients in the adequate group with both Kt/Vwat and Kt/Vbis > =1.7 and patients in the inconsistent group with Kt/Vwat =1.7 was identified, suggesting that their clinical features were similar.
urology & nephrology
What problem does this paper attempt to address?