Abstract:Objective To translate and test the reliability and validity of the short form of Confused Assessment Method( CAM),a diagnostic assessment instrument for delirium. Methods The translation and cultural adaptation was done. The sample was formed by 230 elderly patients aged over 65 years old. The assessors’ reliability and criterion validity( diagnostic validity) was compared by the Diagnostic and Statistical Manual of Mental Disorders,Fifth Edition,which was the gold standard of delirium. Then the sensitivity,specificity,positive predictive value,negative predictive value of Chinese Version of CAM was computed. Results The assessors’ reliability in a sample of 230 patients resulted in a kappa = 0. 780( P< 0. 001). Compared to the gold standard,the sensitivity of Chinese Version of CAM was 97. 37%,the specificity being 96. 88%,the positive predictive value being 86. 05%,and the negative predictive value being 99. 47%,with Kappa = 0. 895( P<0. 001). Conclusions The Chinese Version of CAM has satisfactory reliability and validity. It is easy to operate and can be used as an effective instrument for evaluating the presence of delirium.