The Low Dose MSCT in Evaluating the Nodules or Masses of Lung

DING Juan,XIAO Xiang-sheng,LI Hui-min,LIU Shi-yuan,LI Cheng-zhou,TAO Xiao-feng,ZHANG Chen-shi,ZHU Ting,SHI Yu-lin
DOI: https://doi.org/10.3969/j.issn.1002-1671.2005.08.007
2005-01-01
Abstract:Objective To evaluate low dose MSCT in displaying lesions characters of nodules or masses. Methods Low-dose chest MSCT was performed in 42 cases with nodule or mass.All patients were undergone low-dose plain scan of whole lung.Additional thin axis scans with low-dose and conventional-dose were obtainned at the level of the lesion when!nodule or mass was detected.Conventional-dose scans were performed after administration of intravenous contrast materials in patients detected nodule or mass firstly.5 mm of the two dose and 7.5 mm of the low-dose images were reconstructed using standardization resolution.And VR images of the two dose were reconstructed using standardization and high resolution separately.The difference in form,size and density of nodule or mass on two dose 5 mm image,thin image,and 7.5 mm low-dose image were compared.The influence on VR image quality in different dose and algorithm was also compared.Results There was no difference between two dose images in showing the size and form of nodule or mass.But the standardization deviation of density measured in low-dose thin image was higher than that of conventional-dose image.There was no difference between two dose image in VR image quality,but standardization resolution image was better than high resolution.Conclusion The form,size and density of lung nodule or mass can be displayed accurately in low-dose scanning with standardization resolution image reconstruction and conventional-dose thin axial scan,and simultaneously the radiated dose of patients is much decreased.
What problem does this paper attempt to address?