Determination of Novel Anticancer Drug SLXM-2 by RP-HPLC

SONG Hong-guang,WANG Jian-cheng,ZHANG Qiang
DOI: https://doi.org/10.3321/j.issn:1001-2494.2005.13.020
2005-01-01
Abstract:OBJECTIVE To develop a HPLC method for determining the new anticancer drug SLXM-2. METHODS A separation was performed on a DIKMA?ODS-C18 column(4.6 mm×200 mm,5μm), and mobile phase was acetonitrile-water (2:8) with a flow rate of 1 mL·min-1. The detection wavelength was 199 nm,external standard was used. RESULTS The calibration curve was linear in the concentration range of 0.392-2.02 g·L-1(r = 0.999 8), with an average recovery of (99.7±0.65)%(n = 9). The detection limit of SLXM-2 was 4.4 g·2L-1.CONCLUSION The assaying RP-HPLC assay is convenient, accurate and reliable with good precision, and can be used in the quality control of SLXM-2.
What problem does this paper attempt to address?