Intraocular Pressure Changes after Nd∶YAG Laser Posterior Capsulotomy in Eyes with Bag-Fixated IOL

赵东升,祝肇荣
DOI: https://doi.org/10.3969/j.issn.1674-8115.2004.06.010
2004-01-01
Abstract:Objective To evaluate the effect of Nd : YAG capsulotomy on intraocular pressure in eyes with bag-fixated IOL. Methods One hundred and thirty two eyes of 104 patients were included in the study. Five to fifteen months before undergoing capsulotomy, they had anterior continuous curvilinear capsulotomy, phacoemulsification and in-the-bag intraocular lens implantation. All patients received 0. 2% brimonidine 30 min before and after laser capsulotomy. Results The mean IOP at the baseline, 1 h,l d,l week,l month,6 months after capsulotomy were (13.9 ±3.4) ,(14.5±3.9) , (13.7±3.5) , (13.4±3.4) , (13.4±3.3) , (13.6 ±3.3) , respectively,There were no statistical significant differences among them. Conclusion The IOP elevation after capsulotomy was not signficant in eyes with bag-fixated IOL and prophylatically treated with brimonidine. The study recommends in-the-bag IOL implantation because of its potential benefits to capsulotomy.