Intraocular pressure changes before and after a femtosecond laser procedure for cataract surgery

Ho Seok Chung,Hun Lee,So young Park,Chan Hong Min,Mose Kim,Jae Yong Kim,Hungwon Tchah
DOI: https://doi.org/10.1038/s41598-024-55961-2
IF: 4.6
2024-04-20
Scientific Reports
Abstract:This study aimed to evaluate the changes in intraocular pressure (IOP) before and after femtosecond laser capsulorhexis and lens fragmentation for cataract surgery. We measured the IOP before, immediately, 30 min, and 1 h after the laser procedure in 47 eyes of 47 patients who underwent the femtosecond laser procedure. The mean IOP was 17.51 ± 3.28 mmHg, 30.23 ± 6.70 mmHg, 17.96 ± 3.75 mmHg, and 21.77 ± 5.88 mmHg before, immediately after, 30 min after, and 1 h after the laser procedure, respectively. The mean IOP significantly increased immediately (adjusted P < 0.001) and 1 h (adjusted P = 0.001) after the laser procedure compared with the pre-laser IOP. The mean IOP at 30 min after the laser procedure was significantly lower than that immediately after the procedure (adjusted P < 0.001). However, the IOP 1 h after the laser procedure became higher than that 30 min after the laser procedure. Additionally, the IOP 1 h after the laser procedure was positively correlated with the baseline IOP and negatively correlated with the axial length. In conclusion, this study demonstrated that cataract surgery should be commenced within 30 min after the femtosecond laser procedure to ensure a safe cataract surgery that reduces the risk of increased intraocular pressure.
multidisciplinary sciences
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the change of intraocular pressure (IOP) in femtosecond laser - assisted cataract surgery. Specifically, the researchers evaluated the changes in intraocular pressure before and after femtosecond laser capsulotomy and lens fragmentation. They measured the intraocular pressure of 47 patients before surgery, immediately after surgery, 30 minutes after surgery and 1 hour after surgery to understand the specific change trends of intraocular pressure at these time points. Through this study, the author hopes to provide information on the pattern of intraocular pressure changes, so as to optimize the surgical process and reduce the risks that may be brought by the increase in intraocular pressure, such as serious complications like suprachoroidal hemorrhage. Therefore, the main purpose of this study is to ensure that measures can be taken to protect the safety of patients during femtosecond laser - assisted cataract surgery, especially in terms of intraocular pressure management.