A comparison of real-time ultrasound-guided and landmark approaches to axillary vein cannulation

Yi-zhou HE,Ming ZHONG,Wei WU,Jie-qiong SONG,Jun-feng HUANG,Du-ming ZHU
DOI: https://doi.org/10.3969/j.issn.1674-7372.2016.05.030
2016-01-01
Abstract:ObjectiveTo investigate the clinical effect of real-time ultrasound-guided and landmark approaches axillary vein catheterization.MethodRetrospectively analyzed the data of228 adult patients who required axillary vein catheterization from May 2015 to November 2015 in our hospital. All the patients were randomly divided into ultrasound group (n=126) and landmark-guided group (n=102). The operation time, one-attempt success rate and postoperative complications were compared between the two groups. All patients were taken chest X-rayfilm to confirm the existence of pneumothorax.ResultThe one-attempt success rate of ultrasound group was significantly higher than landmark group (92%︰80%,P<0.01). Ultrasound group had shorter operation time than landmark group [(6.63±0.66) minutes︰(9.26±1.05) minutes,P<0.01]. Also, ultrasound group had lower incidence of postoperative complications than landmark group (P<0.05). ConclusionReal-time ultrasound-guided axillary vein catheterization has a higher one-attempt success rate, shorter operation time and lower incidence rate of postoperative complications and could improve the safety of axillary vein catheterization.