Quantity Study of Nitroxynil by RP-HPLC

GE Xiu-wen,HUANG Yi-jun,WU Ping,YANG Zi-rong,CHEN Wei-dong
DOI: https://doi.org/10.3969/j.issn.1002-1280.2010.08.008
2010-01-01
Abstract:Nitroxynil was determined by a RP-HPLC method.The method was performed with a Agilent Zorbax SB-C18 column(4.6 mm×250 mm,5 μm) at 25 ℃,and the mobile phase was acetonitrile-0.01 mol/L phosphate pH6.5(20∶80,V/V).The flow rate was 1.0 mL/min.The detection wavelength was 273 nm.The result showed that there was a good linear relationship(r=0.999 5) between peak area and nitroxynil concentration at the range of 0.050~1.20 mg/mL,the limit of detection was 2.5 ng/mL,the limit of quantitation was 5.0 ng/mL.The recovery for low,medium and high concentration was 100.21%,99.07% and 101.90% respectively,RSD was 0.48%(n=9).The method is selective and simple that suitable for assay of nitroxynil sample.
What problem does this paper attempt to address?