New two-terminal cable traveling wave fault location method based on FIMD and wavelet transform

Junlong FANG,Chuntao LIU,Bowen ZHU,Xin WEI,Jiali ZHANG,Dongmei LI
DOI: https://doi.org/10.3969/j.issn.1005-9369.2017.01.009
2017-01-01
Abstract:In view of the poor accuracy in present power cable fault location methods,a novel fault location method based on the principle of two-terminal traveling wave was applied to fault location for power cable,the fault location based on fast intrinsic mode decomposition and wavelet transform modulus maxima derivative.Firstly,PSCAD was applied to establish the simulation model of power cable,Phase-to-phase transformation of the measurement point current was carried out,the current component of the measuring point was decomposed by fast intrinsic mode decomposition (FIMD).secondly,the wavelet transform was applied to extract the modulus maxima of the first intrinsic mode decomposition (IMF1) component,and the first derivative was obtained by the modulus maxima,found the singularity of the transient signal.finally,the time of the initial traveling wave arrived at the double-ended of the line,according to the first transient traveling wave,and calculated the fault distance.Result of PSCAD based on test show that the proposed method was of high location accuracy and feasibility.