Effective thermal conductivity of moist aerated concrete with different porosities

Xiao-li YAO,Si-yang YI,Li-wu FAN,Xu XU,Zi-tao YU,Jian GE
DOI: https://doi.org/10.3785/j.issn.1008-973X.2015.06.014
2015-01-01
Abstract:The effective thermal conductivity of autoclaved aerated concrete with different porosities was measured using Hot Disk thermal constants analyzer , w hich is based on the transient plant source technique to investigate ,the thermal insulation performance of autoclaved aerated concrete .Data analysis results show that this instrument has good repeatability and is suitable for the thermal conductivity testing of moist building materials .Results also indicated that the effective thermal conductivity of moist aerated concrete increases monotonously with moisture content rising ,and an inflection point appears w hen the moisture fraction is 15% . When the moisture fraction equal 25% , the thermal conductivity of moist samples is nearly twice that of dry samples .When the moisture fraction is as high as 100% ,the thermal conductivity is 4 times as that of dry samples .The thermal conductivity of aerated concrete decreased with porosity increasing under the same moisture content . The predictor formulas for the effective thermal conductivity of aerated concrete about porosity and moisture fraction was proposed .
What problem does this paper attempt to address?