Distribution Performance Assessment and Structure Optimization of Distributor Applied in Small-diameter Air Conditioner

Yang Gao,Xiaomin Weng,Guoliang Ding,Haitao Hu,Ji Song,Yifeng Gao
DOI: https://doi.org/10.3969/j.issn.0253-4339.2016.02.093
2016-01-01
Abstract:In order to develop a distributor for small?diameter air conditioner with a best distribution performance, a CFD model was es?tablished and experiments with air and water as working fluids were done to evaluate distribution performance of three types of commonly used distributors. The CFD model was validated by the experiments, the structure of the chosen distributor was optimized, and the opti?mized distributor was verified by its application in a room air conditioner. The results show that, the jack?type distributor has the best dis?tribution performance, and its uneven index are less than 6% under rated cooling and rated heating conditions;the CFD model can predict the performance of distributors, with the deviation of uneven index less than 15%. The validated CFD model was used to optimize the structure of the jack?type distributor. Application of the optimized distributor shows that it can enhance the energy efficiency of room air conditioner by 2. 2% -2. 7%.
What problem does this paper attempt to address?