Characterization of fouled Prism membrane and study on cleaning methods

Jun LI,Jianqiang HU,Li GUO,Jiahui SHAO
DOI: https://doi.org/10.16159/j.cnki.issn1007-8924.2018.01.010
2018-01-01
Abstract:Morphology of fouled Prism membranes and contaminants were analyzed by scanning electron microscope (SEM),Fourier transform infrared spectroscopy (FTIR),ion chromatography,ICP-AES and gas chromatography-mass spectrometry (GC-MS).Results showed that the main anions of contanminants were Cl-and SO42-.The main cations were Ca2+,Mg2+ and Fe3+.Organic contaminants were methylbenzene and undecane.Cleaning effects of different concentrations of NaOH and HCl solutions incorporating with ultrasonic were explored.The cleaning method involving acid cleaning (0.9% HCl for 30 min),alkaline cleaning (0.9% NaOH for 30 min) and backwash by deionized water was identified as the optimal procedure for fouling reduction in this study.
What problem does this paper attempt to address?