Experimental investigation of flow visualization and thermal performance of flat-plate single-loop pulsating heat pipes

Chunpeng Zhou,Weinan Hu,Fulong Cui,Fangjun Hong
DOI: https://doi.org/10.3969/j.issn.1000-6516.2017.01.009
IF: 2.134
2017-01-01
Cryogenics
Abstract:The experimental study was conducted to visualize the two-phase flow and test the thermal performance of a single-loop flat plate pulsating heat pipe using R245fa as working fluid.The comparison was made between normal loop and an improved loop with interconnecting channel (IC) between the two vertical parallel channels.It was found that for the normal loop,for a fixed filling ratio,with the increasing of heating power,the two-phase flow experiences oscillation,circulation with alternative change of direction,and circulation with fixed direction.The incorporation of IC provides an additional short-cut for fluid flow and prolongs the oscillation regime,with the fixed direction circulation only occurring at high filling ratio and high working load.With an appropriate filling ratio,IC not only can decrease thermal resistance but also can delay the deterioration of heat transfer.
What problem does this paper attempt to address?