Measurement platform for outgassing rate of insulation materials

Jingyao Yang,Fanjie Li,Bo Wang,Yongxiang Guo,Xiao Liu,Hao Wu,Jianjun Wang,XU Xu,Zhihua Gan
DOI: https://doi.org/10.3969/j.issn.1000-6516.2017.01.002
IF: 2.134
2017-01-01
Cryogenics
Abstract:Insulation materials are widely applied in cryogenic containers.The outgassing rate of thermal insulation material,however,could affect the thermal insulation performance by impairing the vacuum degree in high vacuum environment.Based on the national standard GB/T 31480-2015,a test platform for measuring outgassing rate of insulation materials was established.The measurement of the background outgassing rate verifies the reliability of the test platform.Static method was employed to measure outgassing rate of multilayer thermal insulation materials.This test platform would provide support for the application of thermal insulation materials and the design of cryogenic containers.
What problem does this paper attempt to address?