Experimental study on pressure and evaporation rate of cryogenic liquid boil-off gas re-liquefaction system

Jiqiang Jiao,Shuping Chen,Huiyi Gao,Shufeng Jin,Shuting Yao,Xudong Wang
DOI: https://doi.org/10.16711/j.1001-7100.2018.05.006
2018-01-01
Abstract:In order to study the dynamic process of Boil-Off Gas (BOG) produced by decalescence of cryogenic liquid, and find the method of reasonably controlling pressure and temperature, a set of cryogenic liquid BOG re-liquefaction test system was established. Experiments on pressure, temperature and evaporation rate of a 120 L tank with the high vacuum variable density multilayer insulation (VD-MLI) were conducted with liquid nitrogen as working medium. Besides, the static evaporation rate and heat leak-rate of the tank were calculated. The following findings were obtained based on the experiments. (1) The tank pressure gradually increases with the storage time, and the rising rate is about 10. 9 Pa/s before 480 minutes, then gradually decreases.. (2) The temperature increases from the liquid phase to the gas phase, the temperature inside the liquid phase difference is small, about 1. 2℃. The temperature of the liquid phase and the gas-liquid interface increases with the storage time, the temperature of the gas phase declines gradually, and reaches a relatively stable state after 480 minutes. (3) When the initial filling rate of the tank is 0. 7, the average flow rate declines with storage time. The static evaporation rate is 2. 04%/d and heat leak-rate is 4. 1 W. The results provide a theoretical support for the subsequent research of cryogenic liquid BOG re-liquefaction.