Analysis and Control of Discharge Piping Vibration of a Screw Compressor Used in a Chemical Plant

Zhao Ying,Liu Wenzhi,Shang Guigong,Deng Guo,Feng Jianmei,Peng Xueyuan
DOI: https://doi.org/10.3969/j.issn.1000-8144.2016.08.018
2016-01-01
Abstract:The abnormal vibration of a screw compressor discharge piping had caused the fatigue failure of some thermocouple branches and the unplanned shut down of the system. The causes of the vibration were investigated through acoustic simulation and mechanical analysis of the discharge piping,together with fi eld measurement. It was found that the excessive pulsation,low stiff ness and the fi rst-order structure resonance occurred on the thermocouple branches were the key factors inducing the vibration. Based on the analysis results,reasonable vibration elimination treatments were taken by adding a pulsation attenuator and some pipe supports,changing the arrangement of the discharge piping and reinforcing the thermocouple branches. After the modifi cations,the pressure unevenness all over the discharge piping could meet the requirements of API 619 and the maximum pressure unevenness dropped from 15.50% to 1.53%;the fi rst order natural frequency of the discharge piping increased from 0.90 Hz to 1.67 Hz and the high order natural frequency was away from±10% of the compressor excitation frequency;the first order natural frequency of the thermocouple branches increased from 207.41 Hz to 280.68 Hz and the low order resonance was avoided;the maximum vibration amplitude of the discharge piping dropped from 0.070 mm to 0.017 mm and dropped by 76%;the maximum vibration velocity decreased from 38.8 mm/s to 10.6 mm/s and dropped by 73%. It was indicated that the modifi cations were eff ective.
What problem does this paper attempt to address?