Analysis and Controlling of Pipeline Vibration in Chemical Plant

CUI Wei-sheng,GONG Jian-guo,JIN Tao
DOI: https://doi.org/10.3969/j.issn.1005-0329.2011.10.008
2011-01-01
Abstract:To control the excessive vibration in discharging pipe of a plastic plant,the natural frequency of pipeline,the natural frequency of gas columns and transient response in the vibration are calculated by finite element method.By the measuring data of vibration,and the theoretical calculation result,the cause of pipeline vibration is analyzed.A suggestion to overcome the vibration reduction is made,meanwhile,selection and design method of hydraulic damper and tuned mass damper is presented.The result of the measuring data of the modified pipeline shows that the pipeline modification is effective.