Study of Effects of Digital Filtering and Sensor Characteristics on Velocity Measurement by Correlation Method

袁镇福,周洁,浦兴国,岑可法
DOI: https://doi.org/10.3321/j.issn:0254-3087.2001.01.021
2001-01-01
Abstract:In this paper, the FIR low-pass digital filtering method is first introduced for reducing the effects of noise signals in the experiment of velocity measurement of high-temperature flue gas flowing in pipe. The experimental results indicated that, only one peak presents in the cross-correlation graph, which is in good agreement with theoretical analysis result. Secondly, the temperature and pressure pulse signals of the high-temperature flue gas, obtained by thermocouple and pressure sensor, are introduced to explain the applicability of sensor characteristics.