Researching on Mass Flow Measurement of High -Pressure Turbine Guide Vane

WANG Yi,CHU Wu-li,YANG Yong
DOI: https://doi.org/10.3969/j.issn.1001-3997.2005.11.050
2005-01-01
Abstract:An experiment investigation is always with errors.In this paper,the error of the mass flow measurement system using sonic nozzle through the high-pressure internal guide vane is analyzed,mainly on the errors source,errors distribution theoretic analysis and its application on the influence of experiment instrument choice.An example related to the high-pressure guide vane is given to illustrate the applicable errors distribution method at a given mass measurement uncertainty.The system satisfy the accuracy requirements with low cost.
What problem does this paper attempt to address?