Research on APF Non-Harmonic Detection Control Method With Grid Active Current Forward Feed With CDSC Filter

LI Yunfeng,MENG Runquan,HAN Xiaoqing,ZHAI Jia
DOI: https://doi.org/10.13335/j.1000-3673.pst.2016.2920
2017-01-01
Abstract:Non-harmonic detection control method applied to active power filter (APF) has advantages of elimination of harmonic detection link and reduction of computation burden, but it brings disadvantage of DC voltage fluctuations with load changes. In this paper, based on fluctuation mechanism analysis of APF DC-link voltage under conventional scheme, a modified scheme of improving dynamic response characteristics is proposed to suppress DC-link voltage fluctuations by adding forward-feed of grid fundamental positive sequence current to original control loop. In order to simplify implementation of the proposed scheme inα-β frame, a cascaded delayed signal cancellation (CDSC) filter is designed to obtain fundamental positive sequence current signals. In addition, as steady-state grid currents and voltages share the same phase signal, active power current calculations are replaced with an approximation algorithm. Validity of the proposed scheme is verified via simulations and experiments. Compared with conventional non-harmonic detection control method, DC-link voltage restoration is accelerated and its stability is enhanced in the proposed scheme, and power consumptions of APF and source current unbalance factor are reduced as well.
What problem does this paper attempt to address?