Shunt APF Control Strategy Based on Multiple Synchronous Rotating Transform

王跃,杨昆,钟晓剑,陈国柱
DOI: https://doi.org/10.3785/j.issn.1008-973x.2013.04.022
2013-01-01
Abstract:A novel selective low order harmonic current control strategy was proposed based on multiple synchronous rotating transform in order to improve the compensation flexibility of shunt active power filter(APF).Each couple of harmonics was converted to a pair of 3rd harmonics by a specific synchronous rotating transform.Then the complete low order harmonic current detection can be realized by the superposition of several synchronous rotating transforms with different rotating frequency or rotating direction.A band pass filter of which the selective frequency is three times of the fundamental frequency was designed in order to detect the 3rd harmonics.Equivalent control plant of shunt APF was built.Double-loop control strategy which consists of inner PI control and outer repetitive control was adopted to improve the precision of harmonic current compensation.Simulation model was constructed,and experiment was performed on a 16.5 kVA rated APF prototype.Simulation and experimental results showed the validity and feasibility of the proposed method.
What problem does this paper attempt to address?