Flow Distribution Characteristics of Intermediate Headers of a Supercritical Once-through Boiler's Water Cooled Walls, Operating Under Variable Pressure Conditions
Yu-qin ZHU,Ya-hong LI,Qin-cheng BI,Ting-kuan CHEN
DOI: https://doi.org/10.3321/j.issn:1000-6761.2007.05.002
2007-01-01
Abstract:Flow distribution characteristics, of intermediate distribution headers between water walls, under sub-critical pressure conditions, of a domestic manufactured 600 MW once-through boiler, has been studied. The effect of the medium's pressure on flow distribution characteristics, in the vertical water wall tubes connected with the header, was studied under the following conditions: pressure p = 12-21 MPa, mass flow G = 400-1200 kg/m2 · s, steam content x = 0-1.0. Results show that the non-uniformity, of flow distribution among the parallel connected branch pipes, reduces with the header's increasing pressure and the inlet mass flow. In case the inlet mass flow contains little steam, then flow distribution non-uniformity in the branch pipes increases with increasing steam content; but as soon as the inlet steam mass content exceeds 0.6, non-uniformity of flow distribution decreases with increasing steam content at inlet.