Experimental Study of Intermediate Header Flow Distribution Characteristics of a Supercritical Once-through Boiler Operating at Variable Pressures

朱玉琴,毕勤成,陈听宽
2009-01-01
Abstract:In the light of the structural and parameter features of an intermediate header serving as a transition connection between the spiral coil-tube water-wall at the lower part of the furnace and the vertical tube water-wall at the upper part of the fur-nace in a 600 MW supercritical boiler,the distribution characteristics of gas-liquid two-phase flows in the intermediate header of the supercritical boiler at a load of 35% ECR (Economical Continuous Rating) ,50% ECR and 75% ECR were simulated by using an air-water test loop.Through observations and a high-speed photographic method,the flow pattern in parallel branch tubes of a distribution header was measured and analyzed. By using a quick-closing valve and friction re-sistance method,measured respectively were the phase and flow distribution among various branch tubes. The test results show that at three operating conditions and with inlet dryness ranging from x = 0.7 to 0.95,the flow distribution of the air-water two-phase flows passing through the parallel branch tubes of the distribution header is comparatively uniform,and in most cases,the flow rate deviation is less than 10%.
What problem does this paper attempt to address?