Online Calibration of Electrical Capacitance Tomography Applied in Pneumatic Conveying

YANG Dao-ye,ZHOU Bin,XU Chuan-long,WANG Shi-min
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.14.008
2010-01-01
Abstract:Electrical capacitance tomography(ECT)is a robust method for process monitoring of pneumatic conveying. For the variation of material category or property,the commix permittivity of two-phase flow changes,which results in the measurement error,so that the new measured material need to be recalibrated.Normally,in calibration,it is necessary to remove the ECT sensor from the transportation pipeline and measure the capacitances when filled with a low permittivity material and a high permittivity material.A new calibration method of ECT system used in pneumatic conveying was introduced.The model of ECT sensor was built,and the relative error of the capacitance model was analyzed by finite element method(FEM)simulation.The permittivity of conveyed material was obtained by sampling the monitored object so that the capacitances of ECT sensor can be calculated according to the pre-calibrated relationship between capacitance and permittivity.This calibration method needn’t dismantle ECT sensor,which doesn’t disturb the process of pneumatic conveying.
What problem does this paper attempt to address?