Study on Voidage Measurement of Gas-solid Fluidized Bed by Using Electrical Capacitance Tomography

黄志尧,冀海峰,王保良,李海青
DOI: https://doi.org/10.3321/j.issn:1003-9015.2002.05.004
2002-01-01
Abstract:Based on electrical capacitance tomography technique, a new method for the on-line voidage measurement of gas-solid fluidized bed was proposed. A 12-electrode electrical capacitance tomography measurement system for the voidage measurement of gas-solid fluidized bed was developed. This system can implement voidage distribution display and global voidage measurement of gas-solid fluidized bed simultaneously. The weighted back projection algorithm was selected as the image reconstruction algorithm to satisfy the requirement of voidage distribution display. A new hybrid image reconstruction algorithm which combines Tikhonov regularization theory with ART (Algebraic Reconstruction Techniques) algorithm was presented to implement the global voidage measurement of gas-solid fluidized bed. The use of Tikhonov regularization theory was to solve the ill-posed problem of image reconstruction and the use of ART algorithm was to improve the quality of the final reconstructed image. Study results showed that the proposed new voidage measurement method is successful. The speed of image reconstruction of voidage distribution display is greater than 25 frames per second and the maximum error of global voidage measurement is less than 5%.
What problem does this paper attempt to address?